Intissar Ferrak and colleagues measured how a round perforated brick made from Red Medjana clay takes up and releases moisture at five temperatures, tested twelve isotherm models and built a temperature-aware description of the material.

a close up of a wall made of cement circles
Photo by Oksana Avramenko on Unsplash

Set a fired clay brick in air held at 30 °C and 80% relative humidity and it will absorb water until its weight stops climbing. Lower the humidity and it releases some. It never quite retraces the path it took going up. At the same 60% humidity, a wall that is drying out holds more water than one that is being wetted, and the distance between those two states is what building physicists call hysteresis. Intissar Ferrak and seven co-authors measured that distance for a single, very common Algerian product.

Their specimen is the round perforated brick made from 100% Red Medjana clay at the BORAS works in Sétif. Each unit measures 5.5 by 9.5 by 21 centimetres and weighs between 1,850 and 1,980 grams. It is formed at 17 bar, compressed at roughly 7 bar to squeeze pore volume down, and breaks at 10.7 megapascals. It is also, by the authors' account, a product with no published hygrothermal description before their paper. That is an odd blind spot for something the paper says is used heavily in masonry and in high demand across Algeria.

Why it matters now is arithmetic. Energy models that predict a building's heating and cooling load need to know how much water its walls hold at a given temperature and humidity. Get that input wrong and the simulation drifts, sometimes toward a smaller boiler than a house actually needs. Algeria's energy transition is an active policy file, and a missing moisture curve is a missing number in every calculation downstream of it.

Sealed jars, saturated salts, and patience

The experiments ran at the Laboratory of Structural Mechanics at Tahri Mohammed University in Bechar, and the method is old enough to feel almost stubborn. Small brick specimens go into sealed jars above saturated salt solutions. Each salt pins the air inside at a known relative humidity, while a bath or oven holds the temperature steady. Then you weigh the samples. Repeatedly. For weeks.

This is the gravimetric method, standardised as EN ISO 12571, and its logic is easy to state: when the mass stops changing, the brick has reached hygroscopic equilibrium with the air around it. That equilibrium water content, plotted against relative humidity, is the sorption isotherm. The team climbed the humidity ladder to trace adsorption, then descended it to trace desorption, at 10, 23, 30, 40 and 50 °C — 283 to 323 kelvin.

Twelve published isotherm equations were fitted to those curves to see which described the brick best. Across all five temperatures the answer was Oswin's equation, selected on high regression coefficients combined with low residual sums of squares and low mean relative error. That selection carries practical weight. You cannot build a temperature-aware model on an equation that only works at one temperature, and the authors say as much in their modelling notes.

white and black round pattern

Photo by Meg on Unsplash

Warmer brick, drier brick

In Oswin's equation, the coefficient "a" scales the height of the curve and "b" sets its shape, and both moved with temperature in a consistent direction as the brick warmed. For adsorption, "a" fell from 2.886 at 10 °C to 2.364 at 50 °C, while "b" crept up from 0.316 to 0.347. For desorption, "a" fell from 3.694 to 3.066 and "b" rose from 0.264 to 0.291. The fits were tight: regression coefficients between 0.989 and 0.995, depending on branch and temperature.

Put those two sets of "a" values side by side and the hysteresis is visible without a chart. At every temperature the desorption coefficient sits well above its adsorption counterpart, which is what lifts the drying branch above the wetting branch. The paper also reports the Huang model as the strongest of those compared, with a regression coefficient of 0.990. The full study is open access in Buildings.

Because "a" and "b" both shifted predictably with heat, the authors did something more useful than crowning a winner among the twelve. They replaced the two constants with functions of temperature and folded those back into Oswin's equation. The result is one expression that returns equilibrium water content from relative humidity and temperature together, in both the wetting and drying directions. It is the piece a simulation engineer would actually put to work.

One comparison in the paper deserves flagging. The bricks and building materials discussed in the wider literature, it states, hold less water than this product at a given humidity. If that holds beyond a single kiln, a wall of these units is a bigger moisture buffer than standard material databases assume.

The gap the models keep ignoring

Plenty of hygrothermal simulations assume wetting and drying follow the same curve. The paper argues that assumption fails for this material, and it treats hysteresis as a complication to model rather than smooth away. The literature it reviews is genuinely unsettled on the point: older studies concluded hysteresis doesn't occur in materials with closed-pore structures, and more recent work reported the opposite. For a perforated brick, whose voids are large and open, that question is not academic.

The authors put their own framing bluntly. "The walls built with this product are smart walls, thanks to the brick perforation that ensures energy control," they write. Round perforations interrupt the path heat takes through the clay, and they also change where moisture collects. A model that treats the brick as a solid lump of fired clay, or that ignores which direction the moisture is travelling, misplaces both.

To test whether their model was more than curve-fitting, the team calculated the isosteric heat of sorption — the energy needed to pull water off the clay surface — by two separate routes. Agreement between the two was read as confirmation that the fitted isotherms and the hysteresis treatment describe one physical system rather than two unrelated datasets.

What one factory can and cannot tell you

This is a characterisation, not a demonstration, and the distinction matters. Everything rests on one brick geometry and one clay body, drawn from a single production line. Red Medjana clay is, by the authors' account, being used in red products for the first time. That makes it interesting. It also makes it unrepresentative of any other clay, and firing schedules differ between kilns in ways that set the pore structure the whole moisture story depends on.

Then there is the method's own rhythm. Gravimetric sorption measurements wait for equilibrium, and equilibrium in a dense fired clay body can take weeks at each humidity step. Real walls don't sit still that long: they see a hot afternoon, a cold night, a week of rain, a dry summer. The five temperatures here span a useful range, but a south-facing wall in the Algerian high plateaus will spend part of the year outside it.

Being precise about what the isosteric heat check proves is fair to the authors. Both calculations draw on the same measured isotherms, so their agreement is evidence of internal consistency, not independent proof that the models predict a real wall's behaviour across a year. That test needs a wall assembly and a full climate-year simulation. A skeptical reviewer would ask for those next, along with samples pulled from more than one kiln.

From brick samples to drying kilns

The thread continues in Ferrak's doctoral work at Université Frères Mentouri Constantine 1, where her thesis on forced-convection heat transfer takes the same product and points it at the factory floor rather than the finished wall. Its subject is drying: how to move heat and moisture through wet round perforated bricks more efficiently before they are fired.

The thesis abstract spells out the logic. A well-dried, well-fired brick gives a construction that lasts and resists climatic conditions, which in turn cuts energy use and greenhouse gas emissions. It also reports geotechnical characterisation of the raw clay — an identity card for the material — on the argument that classifying the raw material properly is a precondition for understanding how the finished brick behaves.

Read the paper and the thesis together and a longer arc shows up. First you know what the clay is. Then you know what the fired body does with water at five temperatures, and you hold an equation that reproduces it. Then you tune the kiln. Somewhere after that comes the step the building industry actually needs: dropping that equation into a whole-wall model and checking whether it changes the predicted energy bill.

That last step has not been taken for this brick. When it is, the payoff is concrete — a masonry unit whose moisture behaviour is documented well enough that an engineer in Constantine or Chlef can size a wall on measured evidence instead of a default value borrowed from a database built for European products.

For now the paper offers something narrower and still useful: a measured, temperature-dependent, hysteresis-aware sorption description of one brick that previously had none, plus a model that fits it to a regression coefficient above 0.98 in every direction tested.

  • building-materials
  • sorption-isotherms
  • hysteresis
  • round-perforated-brick
  • hygrothermal-behaviour
Portrait of Jarrod Kanizay
About the author

Jarrod KanizayView author

Academic Jobs In House Author

Visionary leader transforming academic recruitment with 20+ years in higher education.

Discussion

Sort by:

Be the first to comment on this article!

You

You’ll be asked to sign in before your comment is posted.

Browse by Faculty

Browse by Subject

Frequently Asked Questions

🧱What did the Ferrak et al. study actually measure?

The team measured the equilibrium water content of round perforated brick specimens held at known relative humidity and temperature, then repeated the measurement while humidity rose and while it fell. Five temperatures were used: 10, 23, 30, 40 and 50 °C. The experiments ran at the Laboratory of Structural Mechanics at Tahri Mohammed University in Bechar, Algeria, and the results were published in Buildings in 2023.

💧What is a sorption isotherm, in plain terms?

It is a graph of how much water a material holds once it has settled into balance with the air around it, plotted against relative humidity at a fixed temperature. The measurements here follow the gravimetric method standardised as EN ISO 12571: samples sit in sealed jars above saturated salt solutions, each salt holding a set humidity, and are weighed until their mass stops changing.

🔄What is hysteresis in a brick?

It is the gap between the wetting curve and the drying curve. At the same relative humidity, a brick that is drying out holds more water than one that is being wetted. The paper reports this gap at every temperature tested, and its fitted coefficients show it directly: the desorption values of Oswin's "a" coefficient sit well above the adsorption values at all five temperatures.

🌡️Why does temperature matter for moisture in brick?

Warmer air at the same relative humidity holds less absolute moisture, and the clay surface gives water up more easily. The study found that raising temperature lowered the equilibrium water content. In practice, a wall that is 15 °C at night and 45 °C in direct sun is not behaving like a single curve taken at room temperature — which is why a temperature-dependent model matters for energy simulation.

🏗️What is a round perforated brick?

It is a fired clay masonry unit with round voids running through it, which reduces weight and interrupts the path heat takes through the material. The brick studied here is made from 100% Red Medjana clay, measures 5.5 by 9.5 by 21 centimetres, weighs 1,850 to 1,980 grams and has a breaking strength of 10.7 megapascals. It was supplied by the BORAS works in Sétif, Algeria.

📐Which equations fitted the data best?

Of the twelve isotherm equations tested, Oswin's model gave the best fit across all five temperatures, judged on high regression coefficients with low residual sums of squares and low mean relative error. The paper also reports the Huang model as the best of those compared, with a regression coefficient of 0.990. The authors' own model is built on Oswin's equation with its two coefficients rewritten as functions of temperature.

⚙️What is isosteric heat and how was it used here?

Isosteric heat of sorption is the energy required to remove water from a surface at a constant moisture content. The team calculated it by two separate methods as a validation step. Because both calculations use the same measured isotherms, their agreement confirms the models are internally consistent rather than proving they predict a whole wall's real-world behaviour.

📍Who carried out the research and where?

The eight authors are affiliated with the Laboratory of Applied Energetics and Pollution at Université Frères Mentouri Constantine 1 in Algeria, the Interdisciplinary Research Center for Advanced Materials and the mechanical and chemistry departments at King Fahd University of Petroleum and Minerals in Dhahran, Saudi Arabia, and the Laboratory of Theoretical Physics and Materials at Hassiba Benbouali University of Chlef. Rami K. Suleiman is the corresponding author.

⚠️What are the study's main limitations?

All samples came from a single brick geometry, a single clay body and one production line, so the results are material-specific. Gravimetric measurement waits for equilibrium, which is slow, and the five temperatures do not cover every condition a real wall experiences. The paper does not include a whole-wall or whole-building simulation, so the effect on predicted energy use remains an inference rather than a measured result.

🏠How could this change building energy modelling?

Hygrothermal simulation tools need sorption curves as inputs. If those inputs come from a single temperature, or if hysteresis is ignored, predictions of moisture accumulation and heating or cooling demand can drift. A temperature-aware description for a brick that is widely used in Algeria gives modellers a measured alternative to default values borrowed from databases developed for other materials.

🎓What comes next for this line of research?

Ferrak's doctoral thesis at Université Frères Mentouri Constantine 1 extends the work to forced-convection heat transfer during drying of round perforated bricks made in Algeria, alongside geotechnical characterisation of the raw clay. The obvious next step for the published study is a whole-wall simulation using the new temperature-dependent model, plus samples from additional kilns to test how far the findings travel.

📖Is the paper open access?

Yes. It was published in Buildings, volume 13, issue 11, article 2804, on 26 October 2023, and is available under a Creative Commons Attribution 4.0 licence. The full text and figures can be read through the DOI record.