About the Project This project is one of a number in competition for a studentship from the Faculty of Engineering
and Design at the University of Bath. If successful, this studentship is expected to commence 04 October 2027. An alternative start date may be possible if agreed with your intended supervisors and the Doctoral College. Project Background: The success of natural ventilation (NV) for improving indoor air quality (IAQ), energy efficiency and mitigating airborne infection risks in buildings is well documented. However, this success largely depends on how the fresh outdoor air is distributed across the space (i.e. local ventilation effectiveness (LVE) performance). Field studies (such as Maddalena et al., 2015; Dorizas et al., 2015; Cook et al., 2023; Malki-Epshtein et al., 2023) showed that despite of ventilation systems complying with minimum suggested fresh air flow rates (and often exceeding it by multiple times), targeted results could not be achieved as the measured indoor CO2 levels were regularly multiple times (e.g. 2-4) above the targeted value of 1000 ppm. As suggested by (Mustafa 2021 and Cook et al., 2023) one of the main reasons of this poor performance is the poor LVE. Design guidance documents (such as ASHRAE 62.1 (ASHRAE, 2022) and CIBSE Guide A (CIBSE,2021) suggest using higher air flow rates to compensate for poor LVE. However, increased air flow rates do not necessarily result with IAQ and causes higher energy consumption as it effects building heating and cooling demands. Therefore, instead of trying to compensate for poor LVE by increasing air flow rates, systems with better LVE should be designed and operated. However, our knowledge of improving LVE performance in NV systems is limited. While the individual effect of some of the parameters (such as window layout, effective opening area, room depth, internal heat gain distribution and supply air flow rate ) on LVE was quantified by previous research by the supervisor (i.e. Mustafa, 2021) through a parametric analysis, the combined effect of the parameters and the combinations needed to achieve an optimal ventilation design and operation could not be explored. Therefore, as a key deliverable, the project will create a practical analytical model that can easily be used by ventilation designers and operators to improve the LVE in NV systems. The project will use computational fluid dynamics and machine learning methods achieve this. The study is timely and significant as the findings will have substantial impacts on IAQ, energy efficiency and airborne infection risks in buildings. Candidate requirements: A previous knowledge and skill in finite volume computational fluid dynamics (preferably ANSYS) and machine learning is preferable but not essential. Applicants must have, or be about to obtain, a UK Honours degree 1st or 2.1, or international equivalent. A master’s level qualification would also be advantageous. Non-UK applicants, who are not currently studying in the UK, must meet the programme’s English language requirement before the application deadline – no exceptions will be considered. Enquiries and Applications Informal enquiries are encouraged. Direct these to Dr Murat Mustafa - mm3714@bath.ac.uk Please follow the below instructions carefully. You must make a formal application via the University of Bath’s online application form for a PhD in Civil Engineering Please note that you can apply for a maximum of two PhD projects on this programme. In the ‘Funding Your Studies’ section, you must select ‘University of Bath URSA’ from one of the drop-down menus. In the ‘Your PhD project’ section, you must quote the project title in the PhD project title field, and you must quote the lead supervisor’s name in the field ‘Name of intended supervisor at University of Bath.’ If you are applying for two projects, you must quote the project title for your second choice project in the field ‘Project 2 Title’ and the lead supervisor’s name in ‘Name of intended supervisor for 2nd choice project at University of Bath. You must ensure that you follow the above steps correctly. Failure to complete these steps will cause errors in the automated processing of your application and may mean that you are not considered for a particular project. Equality, Diversity and Inclusion We value a diverse research environment and strive to be an inclusive university, where difference is celebrated and respected. We encourage applications from under-represented groups. If you have circumstances that you feel we should be aware of that have affected your educational attainment, then please feel free to tell us about it in your application form. The best way to do this is a short paragraph at the end of your personal statement. The Disability Service ensures that individuals with disabilities are provided the support that they need. If you state if your application that you have a disability, the Disability Service will contact you as part of this process to discuss your needs. Keywords Natural ventilation, ventilation effectiveness, built environment, nearly zero energy building (nZEB), energy efficiency in buildings, energy demand in buildings, indoor airborne disease transmission, SARS-VoV-2, computational fluid dynamics in ventilation design, machine learning in built environment. Funding Notes Applicants will be considered for a studentship. The Faculty of Engineering and Design at the University of Bath has studentships available for Home and Overseas students. However, in line with UKRI policy, the number of studentships available to Overseas students are capped. Studentships cover tuition fees, provide a £1k per annum training support fee, and a maintenance stipend (£21,805 2026/27 rate). International students will be required to cover the cost of a Student visa and Immigration Health Surcharge from personal funds. References Cook, MJ., Adamu, Z., Ciric, L., Hathway, E. A., Malki-Epshtein, L., Fitzgerald, S., Jones, B., Woolf, D., Cropper, P., Iddon, C., Matharu, R., Mustafa, M., Adzic, F., Oladokun, M., Argumedo, P., Roberts, B., Vangeloglou, E., Hajaali, A., Cheung H.Y.W., Wild, O. and Canales, M (2023) Findings and Guidance for Airborne Infection Resilience, AIRBODS. Available at: https://airbods.org.uk/publications/ . Dorizas, P.V., Assimakopoulos, M.N., Helmis, C. and Santamouris, M. (2015) An integrated evaluation study of the ventilation rate, the exposure and the indoor air quality in naturally ventilated classrooms in the Mediterranean region during spring. Science of the Total Environment, 502, 557-570. Maddalena, R., Mendell, M.J., Eliseeva, K., Chan, W.R., Sullivan, D.P., Russell, M., Satish, U. and Fisk, W.J. (2015) Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making. Indoor Air, 25(4), 362-370. Malki-Epshtein, L., Adzic, F., Roberts, B.M., Hathway, E.A., Iddon, C., Mustafa, M. and Cook, M. (2023) Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2. Building Services Engineering Research and Technology, 44(2), pp.113-133. Mustafa, M., 2021. Local ventilation effectiveness of single-zone naturally ventilated spaces (Doctoral dissertation, Loughborough University).