A new harmonisation of 19 life cycle assessments of biosolids processing finds anaerobic digestion has the lowest global warming potential, incineration and composting the highest, and identifies the electricity mix as the single biggest driver of disagreement between studies.

A wooden block that says biometric on it
Photo by Markus Winkler on Unsplash

Force 19 published life cycle assessments of sewage sludge onto the same accounting rules and one technology's average climate footprint jumps 71 percent. Another's spread of results contracts by 46 percent. A ranking that has been murky for two decades suddenly takes a shape.

That exercise is the core of a paper in Environmental Science & Technology by Jingwen Luo, Ruth Fisher, Shamim Aryampa, Sven Lundie and Thomas Wiedmann. Lundie, an affiliated lecturer in the Department of Socioeconomics at the University of Hamburg and a partner at the sustainability consultancy ERM in Hamburg, has been circling this question since a 2001 life cycle study of Sydney's biosolids options. The authors describe the new work as the first harmonised baseline covering the sector's comparative literature rather than one city's choices.

The timing is not accidental. The cheapest disposal route is under pressure. The US Environmental Protection Agency's January 2025 draft risk assessment for PFOA and PFOS in sewage sludge modelled human health risks at concentrations as low as one part per billion, and Maine has already banned land application of sludge outright. Utilities that once spread biosolids on farmland are now pricing thermal plants instead — equipment that costs tens of millions and runs for decades.

Lundie and his co-authors do not pick a winner for any individual utility. What they produce is something more useful to anyone signing off a capital project: a defensible benchmark, plus a short list of the assumptions that actually decide which technology looks best.

Why two studies of the same plant could disagree by a factor of two

Life cycle assessment (LCA) is an accounting method. You define a unit of work, add up every input and emission from cradle to grave, and express the total in a single impact category. Here the unit is one dry tonne of sewage sludge processed, and the category is global warming potential (GWP) — the same family of numbers behind carbon footprints, measured in kilograms of carbon dioxide equivalent.

The trouble is that LCA carries a thousand judgement calls inside it. Where does the system boundary sit? Is the diesel burned hauling biosolids to a farm inside the fence or outside it? Do you credit the system for the natural gas displaced when digested sludge substitutes for mineral fertiliser? Which database supplies the emissions factor for the electricity the plant buys?

Change those choices and the answer moves. A lot. It is like comparing house prices when one agent quotes the sale price and another quotes the price plus stamp duty, legal fees and a new roof. Both are honest. The comparison is nonsense.

The team screened 926 papers from Scopus and Web of Science, reviewed 86 in detail, then applied a nine-criterion filter covering boundary transparency, inventory reporting and how avoided products were handled. Nineteen studies survived. They cover four configurations: anaerobic digestion followed by land application (AD), composting followed by land application (COMP), incineration with ash sent to landfill (INC), and pyrolysis with biochar returned to land (PY).

Harmonisation then aligned system boundaries and rebuilt every background dataset from Ecoinvent v3.10, a globally averaged supply-chain database. Deliberately, the authors left operating parameters alone — electricity consumption, process emissions, digester performance. They were standardising the bookkeeping, not flattening the engineering. Heat recovery was the clearest example: it depends on whether a district heating network happens to run past the plant, so only studies that originally claimed that credit kept it.

Only GWP was harmonised. The authors say why plainly: it drives policy, it is site-generic, and it is the indicator least distorted by differences in impact assessment methods.

What the cleaned-up numbers show

Anaerobic digestion comes out with the lowest mean harmonised GWP of the four. Composting averaged 291 kilograms of CO2 equivalent per dry tonne. Incineration averaged 481. Pyrolysis averaged −138 — net negative, thanks to carbon locked into biochar — but with the widest spread of results even after harmonisation, a signal of how much installations differ and how young the technology is.

Processing systemHarmonised mean GWP (kg CO2-eq per dry tonne)Effect of harmonisation
Anaerobic digestion, then land application (AD)Lowest of the fourSpread down 46 percent, mean largely unchanged
Composting, then land application (COMP)291Spread reduced
Incineration, ash to landfill (INC)481Spread down 47 percent, mean up 71 percent
Pyrolysis, biochar to land (PY)−138Spread reduced, still the widest range

Incineration's 71 percent jump deserves attention because it runs against intuition. The cause was energy accounting. Several studies had claimed credit for heat recovered by burning biosolids without counting the heat spent drying the sludge first. Once that was fixed, the average energy balance across studies settled at 703 ± 391 kilowatt-hours per dry tonne, and the credit shrank. Energy recovery still offset between 39 and 75 percent of total impacts in every study included. It never reached net zero.

For anaerobic digestion the credits run the other way. Energy recovery supplied 46 to 69 percent of total benefits, avoided mineral fertiliser production added 14 to 31 percent, and avoided fertiliser application a further 10 to 22 percent. What remains is direct emissions: methane and nitrous oxide from the digester, the cogeneration unit and the soil after spreading.

white and black labeled book page

Photo by Brett Jordan on Unsplash

Ninety-two inputs, and the handful that actually move the result

Flattening the spread is one job. Explaining where the spread came from in the first place is the paper's more original contribution. The authors introduce a technique they call partial harmonisation: instead of correcting every methodological choice at once, they adjust one input at a time and watch how much the results converge. They ran this across 92 separate LCA inputs, from the electricity mix down to the polymer used in dewatering.

The results narrow the field fast. The electricity mix was the most influential background input across all four systems, and for anaerobic digestion it carried an average harmonised value of 162 kilograms of CO2 equivalent per dry tonne. For incineration, the way energy recovery was bounded mattered most, worth 210 kilograms per dry tonne and shifting the spread by 12 percent. For composting, methane and nitrous oxide escaping the windrows and piles dominated everything else, at 163 kilograms per dry tonne and a 37 percent shift in spread.

Pyrolysis threw up a surprise. The biggest source of variation was not the reactor or the biochar but dewatering consumables — calcium oxide and ferric chloride in one study, powdered activated carbon in another — worth 199 kilograms per dry tonne and a 43 percent swing. Credit for carbon sequestration, included in only three of the seven pyrolysis studies, was worth 163 kilograms per dry tonne when extended to the rest.

The paper also catches a data-recycling problem that quietly corrupts meta-analysis. Five of the reviewed AD studies reported methane emissions from land application. Three of them gave identical figures, 3.18 kilograms per dry tonne, because two later studies copied numbers from the first despite covering three different countries. Artificial consistency of that kind makes a variable look stable when it is not. A similar issue dogs electricity recovery, where reported values run from 113 to 882 kilowatt-hours per dry tonne and only about 40 percent of studies used primary industry data.

The full harmonised results, and a downloadable spreadsheet the authors call the Biosolids LCA Benchmarking Tool, are published with the paper, which is available through its DOI at the American Chemical Society.

The grid picks the winner

Averages are only half the story, so the team ran a Monte Carlo simulation — thousands of random draws from the harmonised distributions — to estimate how often one technology beats another. Anaerobic digestion and pyrolysis outperformed incineration and composting with more than 80 percent probability across every country assessed.

But the top spot changes with the map. Anaerobic digestion had the lowest average GWP in India and Australia. Pyrolysis performed best in France and Denmark. The reason is the electricity supply chain. For AD, average GWP fell as the carbon intensity of the grid rose, with a regression coefficient of −584.8 and p below 0.001: a dirtier grid makes the displaced electricity more valuable, so the credit grows. In countries already running low-carbon power, that advantage thins and pyrolysis's stored carbon starts to look better. Phosphorus fertiliser substitution pushed in the same direction, at −19.5 and p below 0.001.

The practical consequence is that no country can import another's ranking. A utility in Tasmania and a utility in Queensland face materially different answers from the same four technologies.

What the method cannot tell you

The authors are unusually direct about the limits, and their caution is worth taking seriously. Harmonised results can only be as good as the studies feeding them, so existing gaps in geographical, technological and temporal coverage get carried forward. The paper calls its outputs screening-level insights for benchmarking, not a substitute for a site-specific LCA built on primary data.

Only global warming potential was harmonised. Construction and demolition impacts were excluded for lack of consistent data, and the authors note those could matter for eutrophication and metal depletion. The sample is small: seven studies each for composting and pyrolysis, which raises the influence of any single outlier. Partial harmonisation also examines inputs one at a time, so it misses interactions — more dewatering chemical can lower sludge moisture and cut drying energy downstream, for example, and that trade-off disappears in a one-at-a-time analysis.

A sceptical reader might add a further concern. Averages drawn from 19 studies can smooth over exactly the operational detail a plant manager needs, and the Ecoinvent background data represent generic technologies rather than a specific supply chain. The authors anticipate the objection by building the benchmarking tool, which lets practitioners swap in their own foreground assumptions rather than accept the global average.

There is also a regulatory blind spot the paper does not resolve: GWP says nothing about per- and polyfluoroalkyl substances (PFAS), the persistent chemicals driving much of the current policy pressure. The EPA declined to quantify incineration risks for PFOA and PFOS because of data gaps on destruction efficiency, a gap the agency's draft assessment states openly. A technology can win on carbon and still lose on contaminants.

The man behind the method

Lundie's route into this problem was unconventional. An industrial engineer trained at the Karlsruhe Institute of Technology, he took a PhD at Leuphana University Lüneburg on decision-making in LCA and the role of societal values in it, then spent years inside the machinery that produces these numbers — as a principal consultant at Sphera, the software and database firm formerly known as thinkstep, and before that as an associate professor in sustainable water management at UNSW Sydney.

He now splits his time between Hamburg, where he teaches and researches in the Faculty of Business, Economics and Social Sciences, and ERM, where he leads the Corporate Sustainability and Climate Change team for Central Europe. That dual position is worth flagging for readers weighing the paper's industry relevance: it is written by someone who sells sustainability advice to companies and who has spent two decades publishing on biosolids. The paper itself declares no competing financial interest.

Funding came from the Australian Research Centre's Training Centre for the Transformation of Australia's Biosolids Resource at RMIT University, under award IC190100033 — an arrangement that puts industry partners in the same room as the researchers, which may explain why the output includes a usable spreadsheet alongside the analysis.

Where this goes next

The near-term use is unglamorous and valuable. A utility weighing digestion against pyrolysis can now benchmark its own LCA against a harmonised reference before spending money on consultants, and can see which three or four assumptions would flip its conclusion.

Over the next five years, expect the standardisation argument to move from papers into procurement. If the electricity mix and the treatment of energy recovery dominate the variance between studies, those are exactly the fields a regulator or a lender could require to be declared — much as financial reporting standardised depreciation schedules. The authors call for sector-specific methodological frameworks developed jointly by research teams and industry bodies, with policy support.

The tool will need to keep up. Its own developers say it requires continuous updating with newer, higher-quality studies, especially for pyrolysis, where a handful of installations currently carry the weight of an entire technology. And as grids decarbonise, the credit that currently makes digestion shine in India and Australia will keep shrinking. The ranking in this paper is a snapshot of 2026, not a permanent verdict.

  • pyrolysis
  • life-cycle-assessment
  • wastewater
  • anaerobic-digestion
  • biosolids
Portrait of Jarrod Kanizay
About the author

Jarrod KanizayView author

Academic Jobs In House Author

Visionary leader transforming academic recruitment with 20+ years in higher education.

Acknowledgements:

Discussion

Sort by:

Be the first to comment on this article!

You

You’ll be asked to sign in before your comment is posted.

Browse by Faculty

Browse by Subject

Frequently Asked Questions

📊What does harmonising a life cycle assessment actually mean?

Harmonisation means recalculating published studies so they use the same system boundaries and the same background data, while leaving each study's real operating parameters alone. In this paper the authors standardised which processes counted inside the boundary and rebuilt supply-chain data from Ecoinvent v3.10, but kept each plant's electricity consumption and process emissions as reported. The point is to separate genuine technological differences from differences in bookkeeping.

♻️Which biosolids processing technology has the lowest carbon footprint?

Anaerobic digestion followed by land application came out with the lowest mean harmonised global warming potential of the four systems studied. Composting averaged 291 kilograms of CO2 equivalent per dry tonne and incineration averaged 481. Pyrolysis averaged −138, which is net negative thanks to carbon stored in biochar, but its results ranged more widely than any other system even after harmonisation.

🏭Why did incineration's climate impact rise by 71 percent?

Several studies had claimed credit for heat recovered by burning biosolids without counting the heat used to dry the sludge beforehand. Once the energy balance was corrected across all included studies, the average credit shrank and the mean harmonised GWP rose 71 percent. Energy recovery still offsets between 39 and 75 percent of incineration's total impacts, but in no included study did it reach net zero.

🌍Why does the best technology change from country to country?

The electricity mix is the most influential background input across all four systems. Anaerobic digestion earns credits for displacing grid electricity, so those credits are worth more on a high-carbon grid. The regression coefficient was −584.8 with p below 0.001. In the country simulations, digestion had the lowest average GWP in India and Australia, while pyrolysis performed best in France and Denmark, where the grid is already clean.

🔍What is partial harmonisation and why is it new?

Full harmonisation corrects every methodological choice at once. Partial harmonisation instead adjusts one LCA input at a time and measures how much the spread between studies narrows. Applied across 92 inputs, it turns a vague complaint about inconsistent methods into a ranked list. The authors present it as a sensitivity analysis for harmonisation itself, and say it can be used alongside or independently of the full protocol.

📚How many studies did the researchers actually use?

They screened 926 papers from Scopus and Web of Science, reviewed 86 in detail, and applied a nine-criterion screening framework. Nineteen studies passed and were harmonised across four processing systems. Anaerobic digestion had the largest evidence base; composting and pyrolysis had seven studies each, which the authors flag as a limitation because single outliers carry more weight in a small sample.

🧰What is the Biosolids LCA Benchmarking Tool?

It is a spreadsheet published as supporting information with the paper. Practitioners can adjust foreground assumptions and background data to generate harmonised results suited to their own site, then benchmark their existing LCA against the harmonised literature. The authors intend it as a starting point for stakeholder discussions and early-stage decisions before a full primary-data study is commissioned.

🧪Does this paper account for PFAS contamination?

No. The harmonisation covers global warming potential only, chosen because it is site-generic and least sensitive to differences in impact assessment methods. Per- and polyfluoroalkyl substances (PFAS) are outside its scope. That matters because regulators are increasingly focused on contaminants rather than carbon, and the US EPA declined to quantify incineration risks for PFOA and PFOS because of gaps in destruction-efficiency data.

⚖️What are the main limitations the authors admit?

They state that harmonised results inherit any gaps or biases in the underlying studies, including weak geographical and temporal representativeness, and should be read as screening-level insights rather than replacements for site-specific LCA. They also note that only GWP was harmonised, that construction and demolition impacts were excluded, that samples for composting and pyrolysis were small, and that partial harmonisation misses interactions between inputs.

💰Who funded the research and were there competing interests?

The work was funded by the Australian Research Centre's Training Centre for the Transformation of Australia's Biosolids Resource at RMIT University, under award IC190100033. The authors declare no competing financial interest. Co-author Sven Lundie holds a dual role as an affiliated lecturer at the University of Hamburg and a partner at the consultancy ERM, which readers weighing the paper's industry relevance may wish to note.

📏What is a dry tonne of sewage sludge and why use it?

A dry tonne (tds) is one tonne of solids with the water removed, which lets researchers compare plants handling sludges of very different wetness. Every inventory figure and result in the study was converted to this common unit so that a wet digested sludge and a dried incineration feedstock could be compared on equal terms.

📄Where can I read the full paper?

Luo, Fisher, Aryampa, Lundie and Wiedmann published the study in Environmental Science & Technology in 2026, volume 60, issue 7, pages 5453 to 5466. The full text is available through the paper's DOI, and the supporting information includes the benchmarking tool and harmonised results for every country with Ecoinvent data.

Biosolids LCA harmonised: which sludge option wins #29954