At a glance
Dr Srilatha Y of Dayananda Sagar Academy of Technology and Management co-authored a study on rGO-WO3-PPy hybrid nanocomposites that detect ammonia at 2 ppm with a 16-second response at room temperature and at 200 °C, with implications for industrial safety monitoring and non-invasive breath diagnostics.
Sixteen seconds. That is how long a thin film of tungsten oxide, reduced graphene oxide and a conducting polymer takes to register two parts per million of ammonia in air at room temperature, according to a study from Bengaluru published in the Journal of Science: Advanced Materials and Devices. When the gas clears, the film's resistance returns to its starting value in 28 seconds.
The response itself is large: 184 percent at that concentration. Five separately fabricated sensors averaged 184.14 percent with a spread of 4.75, and the same device survived 12 on-off cycles without noticeable degradation. At 200 degrees Celsius the film reacts faster still, 4 seconds in and 15 seconds out.
Ammonia is among the most heavily produced industrial chemicals on earth, and it is also a breath biomarker. NIOSH recommends that workers be exposed to no more than 25 parts per million over an eight-hour shift, with a 35 ppm ceiling for short bursts, and treats 300 ppm as immediately dangerous to life or health. A sensor that works at room temperature, without a heater, and still performs at industrial temperatures is the practical target the Bengaluru team set itself. The paper's authors describe that dual-temperature capability as the study's main novelty.
The work comes from R. Triveni, Y. Srilatha, P. Aruna, Prakash R. Somani, Sambasivam Sangaraju and Vijaya Kumar Kambila. Srilatha is an associate professor of physics at Dayananda Sagar Academy of Technology and Management in Bengaluru, where she has taught since 2019; she completed a PhD in physics at IIT Madras in 2007 and has spent the past several years on graphene-oxide composites for gas detection.
Why a nose is not a measurement
Human beings can smell ammonia at a few parts per million, which is useful in a leaking refrigeration plant and useless almost everywhere else. The nose saturates, adapts within minutes, and cannot tell 5 ppm from 15. Regulators, clinicians and farm managers need a number.
The clinical side is the more interesting one. Exhaled breath from healthy adults carries ammonia at roughly 50 to 1,500 parts per billion, while people with failing kidneys breathe out somewhere between 1,500 and 15,000 ppb, because urea that the kidneys can no longer clear is broken down to ammonia in the body. A breath test for that range would be painless and repeated as often as a doctor liked, unlike a blood draw. Getting a cheap sensor to sit in that window, in breath that is close to saturated with water vapour at body temperature, is a separate engineering problem from detecting a tank leak.
Existing ammonia sensors split into two camps, and each has a handicap. Metal oxide devices such as tungsten trioxide respond strongly but usually need to be heated to a few hundred degrees, which means a power budget and a warm-up period. Conducting polymers such as polypyrrole work at room temperature, respond quickly because of their high surface area, and are simple to make, but they can be fussy about humidity and drift over time. The Bengaluru team's bet was that combining the two, with a carbon scaffold to hold everything apart, would produce something better than either.
Three materials, one film
Reduced graphene oxide, or rGO, is what is left when you strip oxygen-containing groups off graphene oxide. The sheets are wrinkled, electrically conductive, and stack badly, which here is an advantage: they form a porous, high-surface-area skeleton. Tungsten trioxide (WO3) is an n-type semiconductor, meaning its charge carriers are electrons. Polypyrrole (PPy) is a p-type conducting polymer, meaning its carriers are positive holes.
A workable analogy is a scrubbing pad. The rGO sheets are the open, tangled fibres that give the pad its surface area. The WO3 particles are the abrasive grains stuck to those fibres, where the chemistry actually happens. The polypyrrole is the binder that coats the whole thing and carries current from grain to grain. None of the three works as well alone as the assembly does.
Making it took two routes. Polypyrrole was grown by oxidative polymerisation: pyrrole was added drop by drop to a cold ammonium persulfate solution over six hours, the mixture turning from dark green to black as the polymer formed, then left for two more days to finish. The rGO-WO3 half was made by chemical co-precipitation, using sodium tungstate as the tungsten source and ascorbic acid as the reducing agent for graphene oxide, with hydrochloric acid driving the precipitation. The two were then combined hydrothermally at four rGO loadings, 1, 3, 6 and 9 percent by weight, labelled rGWP throughout the paper.
What the instruments found
X-ray diffraction showed orthorhombic WO3 alongside semicrystalline polypyrrole. Raman spectra showed the number of defects in the carbon lattice rising as more rGO went in, and shifts in the infrared absorption peaks showed the three components had actually bonded to one another rather than sitting side by side. Electron microscopy put the WO3-polypyrrole particles at roughly 60 to 70 nanometres, scattered across wrinkled sheets, and energy-dispersive X-ray analysis tracked the carbon-to-oxygen ratio from 1.02 to 1.67 across the series, consistent with progressively better reduction of the graphene oxide.
The surface measurements matter most for sensing. Atomic force microscopy put root-mean-square roughness at 124.9 nanometres for the 1 percent film, rising to 464.4 nanometres at 9 percent, and the roughness correlated with gas response at an R-squared of 0.94. Nitrogen adsorption showed a fourfold increase in the available surface area at the endpoints. A rougher, more porous film simply gives ammonia more places to land.
| Measured property | 1% rGO film | 9% rGO film |
|---|---|---|
| Root-mean-square surface roughness | 124.9 nm | 464.4 nm |
| BET specific surface area | 40.23 m²/g | 85.71 m²/g |
| Mean pore diameter | 13.61 nm | 25.96 nm |
| Electrical resistance | 0.683 MΩ | 0.363 MΩ |
| Second-stage thermal decomposition | 441 °C | 503 °C |
Thermal analysis traced two weight-loss events. The first, near 101 degrees Celsius, was adsorbed water leaving, at 6.67 to 6.98 percent. The second was the real decomposition, and it moved steadily upward with rGO content, from 441 degrees Celsius in the 1 percent film to 503 degrees in the 9 percent film, while the mass lost in that step grew from 20.62 to 34.84 percent. Current-voltage sweeps through the origin were linear with an R-squared near 0.99, which is laboratory shorthand for ohmic contact: the films behave like resistors, not like anything with a diode or a barrier in the measurement path. Resistance fell across the series from about 0.68 to about 0.36 megaohms, the conductive graphene giving carriers a shorter road.
Gas testing was run in a sealed chamber held at 35 percent relative humidity, give or take two points, with the humidity controlled by splitting a dry and a water-saturated stream. Baseline resistance was allowed to stabilise for 30 minutes in dry air before each run. The 9 percent film was the clear winner at 2 ppm: a 184 percent response, 16 seconds to respond and 28 to recover at room temperature, 4 and 15 seconds at 200 degrees Celsius. It responded less to hydrogen sulfide, carbon monoxide and ethanol than to ammonia. Full details are in the published paper, which is open access.
Why the resistance climbs instead of falling
Most people expect a gas sensor's resistance to drop when a gas arrives. This one does the opposite, and the reason is worth following because it explains the sensitivity.
In clean air, oxygen molecules settle onto the WO3 surface and pull electrons out of it, leaving an electron-depleted shell around each particle that raises resistance. On the polypyrrole and rGO side, the same oxygen pull creates the opposite condition, a layer packed with positive holes that conducts well. Where the n-type oxide meets the p-type polymer, electrons drift across until the Fermi levels line up, building a built-in potential barrier. Picture a turnstile that lets electrons through in one direction until a queue builds on both sides and the gate stiffens.
Ammonia is a reducing gas and an electron donor. It reacts with the pre-adsorbed oxygen ions on the tungsten oxide, handing electrons back. It also docks onto the polypyrrole and neutralises holes there, an effect the authors call de-doping. The oxide grains get more conductive; the polymer network, which controls the overall current, gets less. Since the polymer dominates, total resistance rises. The graphene is what makes that rise easy to read, because its high surface area and low electronic noise push the signal above the background.
"A key novelty of this study is the dual-temperature operation capability, allowing for high-performance sensing at both room temperature (for non-invasive medical breath analysis) and 200 °C (for industrial monitoring)," the authors write.
The distance between a lab result and a breath test
Several things stand between this measurement and a device in a clinic, and the paper is its own best guide to them.
Humidity was pinned at 35 percent during every test. Real exhaled breath is close to 100 percent relative humidity at 37 degrees Celsius, and water is the classic interferent for conducting-polymer sensors, swelling the polymer and changing its conductivity on its own. The team's humidity control is a strength of the experimental design and also a reminder that the variable has not yet been allowed to roam.
Two parts per million, the concentration where the 16-second response was recorded, sits above the healthy breath range of 50 to 1,500 parts per billion. It overlaps the lower end of what kidney patients exhale, but the paper does not report a detection limit or a calibration curve down through the healthy window, so how the film behaves at 200 ppb is an open question rather than an established one.
Twelve cycles is a short stability test. Polymer-based sensors are known to drift over months as dopants redistribute and films absorb moisture, and the paper does not report shelf life or ageing. Selectivity was checked against a small set of gases rather than the hundreds of volatile compounds in real breath. And the work is a materials study: no human breath samples were collected, and no prototype device was built.
Who paid, and who did what
The acknowledgements credit Dayananda Sagar University in Bengaluru, and note that Kambila's contribution came under an approved project from the Indian Council of Medical Research in New Delhi, file number 17X(3)/Adhoc/53/2022-ITR. Triveni is credited with conceptualisation, methodology and the original draft; Srilatha with resources and data curation; Kambila with supervision and project administration. The journal, published by Elsevier, is fully open access, so the paper can be read without a subscription.
What sixteen seconds buys
A sensor that works at room temperature and again at 200 degrees Celsius is doing two jobs with one material, and that is the part worth watching. Room-temperature operation means a battery-powered badge that does not need a heater. High-temperature operation means the same chemistry can sit in an exhaust duct or a fertiliser plant where the air is hot and dirty.
The group's publication record suggests a systematic push rather than a one-off: the same collaborators reported a nickel-oxide-based rGO thin film for hydrogen sensing in 2025, and a platinum-decorated rGO/SnO2/polypyrrole hybrid for acetone in 2026. Swapping the oxide and the catalyst and keeping the carbon-polymer architecture is how a sensor family gets built. Whether ammonia ends up in a breath clinic or a livestock shed first will depend on the unglamorous work that follows: humidity sweeps, months-long drift tests, and the calibration data that turn a promising response into a number a regulator will accept.
Photo by Vitaly Gariev on Unsplash
- materials-science-research
- environmental-monitoring
- ammonia-gas-sensor
- rgo-wo3-ppy-nanocomposite
- gas-sensing-materials